Sound insulation

The sound insulation rating of a building element or component is determined by means of a measurement on a test bench. The test specimens are usually installed with ideal high-sound-insulating joints in accordance with the relevant standards so that the sound transmission via the building element can be determined without any accompanying ancillary works.

Testing

The measurements are carried out in test benches with suppressed flanking transmission, which are completely decoupled from each other. The average sound pressure level in the transmitter room and the average sound pressure level in the receiver room are measured and evaluated using the tenfold decimal logarithm, depending on the test surface/test opening to the equivalent sound absorption area in the receiver room.

The test results are given as single figures with additional evaluation by the spectrum adjustment values C (e.g. residential activities) and Ctr (e.g. traffic noise) as follows:

  • Airborne sound insulation

Rw (C; Ctr) (dB) rated sound insulation measure

  • Longitudinal sound insulation

Dn,f,w (C; Ctr) (dB) rated standard flanking sound level difference

A total of 4 test benches are available for measuring airborne sound insulation and 1 façade test bench for measuring airborne and flanking sound insulation.

In addition to testing in standard-compliant test benches, we also offer on-site building acoustics testing at the construction site upon request.

Building components / standards

The following building components, among others, can be tested:

  • Windows
  • Doors
  • Gates
  • Facades
  • Roller shutter boxes
  • Joints (small technical components)
  • Wall and ceiling systems
  • Single-pane glass, laminated glass, multi-pane insulating glass
  • Joints, seals (small technical components)

Can’t find your building component? Please get in touch with us!

Kontakt aufnehmen

Excerpt from the relevant standards:

DIN EN ISO 10140-1

Acoustics – Measurement of sound insulation of building components in test chambers –
Part 1: Rules for application for specific products

DIN EN ISO 10140-2

Acoustics – Measurement of sound insulation of building components in test conditions –
Part 2: Measurement of airborne sound insulation

DIN EN ISO 10140-4

Acoustics – Measurement of sound insulation of building components in test conditions –
Part 4: Measurement methods and requirements

DIN EN ISO 10140-5

Acoustics – Measurement of sound insulation of building elements in test conditions –
Part 5: Requirements for test conditions and test facilities

DIN EN ISO 10848-1

Acoustics – Measurement of flanking transmission of airborne sound and impact sound […] –
Part 1: Framework document

DIN EN ISO 10848-2

Acoustics – Measurement of flanking transmission of airborne sound and impact sound […] –
Part 2: Application to lightweight components where the connection has little influence

DIN EN ISO 717-1

Acoustics – Evaluation of sound insulation in buildings and of building elements –
Part 1: Airborne sound insulation

DIN EN ISO 717-2

Acoustics – Evaluation of sound insulation in buildings and of building elements –
Part 2: Impact sound insulation

DIN EN ISO 16283-1

Acoustics – Measurement of sound insulation in buildings and of building elements on site –
Part 1: Airborne sound insulation

DIN EN ISO 16283-2

Acoustics – Measurement of sound insulation in buildings and of building elements in place –
Part 2: Impact sound insulation

DIN EN ISO 16283-3

Acoustics – Measurement of sound insulation in buildings and of building elements in place –
Part 3: Facade sound insulation

 

Please contact us for further building acoustics certification based on other normative standards.

DIN 4109-1 – Sound insulation in building construction – Part 1: Minimum requirements

DIN 4109-2 – Sound insulation in building construction – Part 2: Calculated verification of compliance with requirements

DIN 4109-4 – Sound insulation in building construction – Part 4: Building acoustics tests

DIN 4109-32 – Sound insulation in building construction – Data for the mathematical verification of sound insulation (component catalogue) – Part 32: Solid construction

DIN 4109-33 – Sound insulation in building construction – Data for the mathematical verification of sound insulation (component catalogue) – Part 33: Timber, lightweight and dry construction

DIN 4109-34 – Sound insulation in building construction – Data for the calculation of sound insulation (component catalogue) – Part 34: Facing constructions in front of solid components

DIN 4109-35 – Sound insulation in building construction – Data for the calculation of sound insulation (Component catalogue) – Part 35: Elements, windows, doors, curtain walls

DIN 4109-36 – Sound insulation in building construction – Data for the calculation of sound insulation (component catalogue) – Part 36: Building services

Minimum requirements in Germany:

The national DIN 4109 series of standards regulates the minimum requirements for certain building components, e.g. walls, ceilings and doors, which must be met depending on the structural situation. Due to the scope and the different specifications, we recommend contacting the testing centre.

Ansprechpartner

Michael Ewald

Michael Ewald

(0)8036 674947 – 0

Kontakt aufnehmen