Repeated opening and closing

Windows and external doors shall be opened and closed repeatedly in accordance with DIN EN 1191. In the case of multiple functions such as tilt and turn windows, etc., each function is tested with the same number of cycles. The different opening variants can be tested simultaneously or separately.

Test

To determine the durability of windows and extenal doors, they are repeatedly opened and closed. In the case of multiple functions such as turning and tilting, each function is tested with the same number of cycles. Exception for inactive moving parts such as fixed sashes

The parts affected by the test are the frame, the opening parts (as well as inactive sashes) and all essential, directly involved building fittings including the operating devices, e.g. window handles or door handles.

Relevant standards:

Test standard (s):
DIN EN 1191

Classification standard:
DIN EN 12400

class application number of cycles stress
windows doors
 0    –    
1 5 000 light occasionally
2 Residential construction 10 000 medium light
3 Business 20 000 strong rarely
4 50 000 medium
5 Residential construction 100 000 normal
6 Business 200 000 often
7 Special 500 000 strong
8 1 000 000 very often

According to Table 1, supplemented by Tables A.1 and A.2, each from DIN EN 12400 : 2003-01